Eigenschaften
Technische Daten
Schauspieltyp: Einfachwirkend (Suffix 03) / Doppeltwirkend (Suffix 06)
Feedback -Typ: Standard (HX) / Erweiterte Präzision (HE)
Eingangssignal: 4–20 mA + HART-Kommunikationsprotokoll
Versorgungsdruck: 1,4–8 bar (0,14–0,8 MPa)
Betriebstemperatur: -40°C bis +80°C (Standardversion)
Schutzklasse: IP66 / NEMA 4X, explosionsgeschützt Ex ia IIc T6
Positionierungsgenauigkeit: ±0,5 % FS (HX), ±0,1 % - ±0,2 % FS (HE)
Zertifizierung: ATEX, IECEx, FM, SIL 2 Approved, Low Power Consumption
Grundinformation
Markenname: Valmet Neles
Modellnummer: ND9103HX8T ND9106HX8T ND9203HE8T ND9206HE8T ND7106HX8
Dokumentieren: Valmet ND9000en.pdf
Zahlung und Versand AGB
Verpackung Informationen: Karton-/Holzkistenverpackung
Lieferzeit: 6-8 Wochen
Zahlungsbedingungen: T/T
Versorgungsmaterial-Fähigkeit: 800 Sätze pro Jahr
Produkt-Beschreibung
Valmet Neles ND Series Smart Valve Positioner Product Introduction
Product Overview

The Valmet Neles ND Series, including models ND9103HX8T, ND9106HX8T, ND9203HE8T, ND9206HE8T and ND7106HX8, are advanced smart electro-pneumatic valve positioners. They deliver precise and reliable control for industrial valves.

These positioners use digital technology to ensure accurate valve positioning. They provide real-time feedback for optimal performance in critical process control applications. The devices are loop-powered, integrating seamlessly with 4-20mA control signals and HART communication protocols. This enables remote monitoring and configuration.

Features
  • Smart Digital Control: Utilizes microprocessor-based technology for precise valve positioning and quick response times.
  • Dual Acting & Single Acting Compatibility: Supports both actuator types to suit different valve configurations.
  • HART Communication: Enables remote diagnostics, configuration, and monitoring for improved maintenance efficiency.
  • Robust Construction: IP66/IP67-rated enclosure for reliable operation in harsh industrial environments.
  • Automatic Calibration: Streamlines setup with one-button calibration to reduce installation time.
  • Advanced Diagnostics: Provides real-time data on valve performance, helping predict maintenance needs.
  • Wide Temperature Range: Operates stably in extreme temperatures from -40°C to +85°C.
Technical Specifications
Parameter Details
Input Signal 4-20 mA DC, HART 7 compatible
Supply Pressure 0.2 to 0.7 MPa (2 to 7 bar)
Output Pressure Range 0.02 to 0.6 MPa (0.2 to 6 bar)
Positioning Accuracy ±0.25% of full scale
Enclosure Protection IP66 / IP67
Ambient Temperature -40°C to +85°C (-40°F to +185°F)
Communication Protocol HART 7, FOUNDATION Fieldbus (optional on select models)
Mounting Standard IEC 60534-6-1 / VDI/VDE 3845
Applications

The Valmet Neles ND Series positioners are engineered for critical process control in industries requiring high reliability:

  • Oil & Gas: Onshore and offshore production, refining, and pipeline systems
  • Petrochemical & Chemical: Polymer production, specialty chemical manufacturing, and continuous process plants
  • Power Generation: Thermal power plants, combined-cycle facilities, and waste-to-energy systems
  • Pulp & Paper: Digester control, bleaching processes, and stock preparation
  • Water & Wastewater: Treatment plants, pumping stations, and distribution networks
  • Mining & Metals: Mineral processing, smelting operations, and material handling systems
FAQ

Q: What is the difference between ND9100 and ND9200 series models? A: The ND9100 series is designed for quarter-turn valves (ball, butterfly, plug valves), while the ND9200 series is optimized for linear valves (globe, control valves).

Q: Can these positioners be used in hazardous areas? A: Yes, select models are ATEX, IECEx, and CSA certified for use in Zone 1/21 and Zone 2/22 hazardous locations.

Q: How often do I need to calibrate the positioner? A: With automatic calibration functionality, routine calibration is typically only needed every 2–3 years or after maintenance.

Q: Is HART communication required for operation? A: No, the positioners operate with a basic 4-20mA signal, but HART unlocks remote configuration and diagnostic capabilities.

Contact Us

For inquiries, technical support, or to request a quote, reach out to us directly:

wechat/what's app/phone number:+8613472860702

Our team of industrial automation experts is ready to assist with product selection, configuration, and after-sales support.

Related Products
  • Valmet Neles NDX Series Digital Valve Controllers
  • Valmet Neles Q-DISC™ Control Valves
  • Valmet Neles Ball and Butterfly Valves
  • Valmet Neles Valve Positioner Accessories (Mounting Kits, Sensors)
Bewertungen & Rezensionen

Gesamtbewertung

5.0
Basierend auf 50 Bewertungen für diesen Lieferanten

Rating-Schnappschuss

Die folgende Verteilung zeigt alle Bewertungen.
5 Sterne
0%
4 Sterne
0%
3 Sterne
0%
2 Sterne
0%
1 Sterne
0%

Alle Bewertungen

F
FLOWSERVE MARK ONE Linear Globe Angle Control Valve Spring Cylinder Valve Pneumatic Actuator
Switzerland Dec 1.2025
great price and fast delivery
Empfohlene Produkte
Nehmen Sie Kontakt mit uns auf
Ansprechpartner : Mr. Edward Zhao
Telefon : +8615000725058
Zeichen übrig(20/3000)